Skip to main content

Nodeop Troubleshooting

"Database dirty flag set (likely due to unclean shutdown): replay required"

nodeop needs to be shut down cleanly. To ensure this is done, send a SIGTERM, SIGQUIT or SIGINT and wait for the process to shutdown. Failing to do this will result in this error. If you get this error, your only recourse is to replay by starting nodeop with --replay-blockchain

"Memory does not match data" Error at Restart

If you get an error such as St9exception: content of memory does not match data expected by executable when trying to start nodeop, try restarting nodeop with one of the following options (you can use nodeop --help to get a full listing of these).

Command Line Options for sysio::chain_plugin:
--fix-reversible-blocks recovers reversible block database if
that database is in a bad state
--force-all-checks do not skip any checks that can be
skipped while replaying irreversible
blocks
--replay-blockchain clear chain state database and replay
all blocks
--hard-replay-blockchain clear chain state database, recover as
many blocks as possible from the block
log, and then replay those blocks
--delete-all-blocks clear chain state database and block
log

"Could not grow database file to requested size." Error

Start nodeop with --shared-memory-size-mb 1024. A 1 GB shared memory file allows approximately half a million transactions.

What version of Wire Sysio am I running/connecting to?

If defaults can be used, then clio get info will output a block that contains a field called server_version. If your nodeop is not using the defaults, then you need to know the URL of the nodeop. In that case, use the following with your nodeop URL:

clio --url http://localhost:8888 get info

To focus only on the version line within the block:

clio --url http://localhost:8888 get info | grep server_version

Error 3070000: WASM Exception Error

If you try to deploy the sysio.bios contract or sysio.system contract in an attempt to boot an EOSIO-based blockchain and you get the following error or similar: Publishing contract... Error 3070000: WASM Exception Error Details: env.set_proposed_producers_ex unresolveable, it is because you have to activate the PREACTIVATE_FEATURE protocol first. More details about it and how to enable it can be found in the Bios Boot Sequence Tutorial. For more information, you may also visit the Nodeop Upgrade Guides.